NeoDisc Download

Please download each file individually. The Manual, Resources, and MD5 checksums are available without registration and can be downloaded through the web browser or using command-line download managers (e.g., using wget).

NeoDisc software requires email registration. After registering, you will receive an email with a unique download link. Please ensure that you open the link in the same browser used for registration and that cookies are enabled on the website.

Version 1.7.2 – bugfix 2

Bug Fixes:

• Fixed a rare error where an HLA-typed allele appears as non-available

Version 1.7.2 – bugfix 1

Bug Fixes:

• Fixed an error in the parsing of the configuration file during the MS statistics part

• Improved reliability of the copy of MS data

Version 1.7.2

Version 1.7.2 introduces support for Bruker timsTOF data analysis and adresses bugs identifier in earlier versions.

Major changes:

• Support for Bruker timsTOF data:

Bruker timsTOF data are specified in the following variable in the configuration file: MS_SPECTRA_TIMSTOF_DDA_HLA_I, MS_SPECTRA_TIMSTOF_DDA_HLA_II, MS_SPECTRA_TIMSTOF_DIA_HLA_I, MS_SPECTRA_TIMSTOF_DIA_HLA_II

Thermo Orbitrap data keep the same variable names in the configuration file: MS_SPECTRA_DDA_HLA_I, MS_SPECTRA_DDA_HLA_II, MS_SPECTRA_DIA_HLA_I, MS_SPECTRA_DIA_HLA_II

The syntax for defining MS_SPECTRA_SAMPLES in the configuration file has been simplified:

• Injections are now grouped by sample (This means that the sample name is written only once, followed by all its associated MS files) as follow: sampleA:ms_file1,ms_file2;sampleB:ms_file3,ms_file4;… Colon ( : ) separates the sample name from its list of MS files. Comma ( , ) separates multiple MS files belonging to the same sample. Semicolon ( ; ) separates different samples

Removed Comet-NewAnce module: This module was removed due to its limited applicability (restricted to Thermo DDA data). NeoDisc now relies on the FragPipe-based workflow, which supports both Thermo and Bruker data in DDA and DIA modes.

Minor changes:

Updated proteowizard (msconvert) version in the container (3.0.25182)

• Convert only thermo DIA data to mzML (this conversion is required for DIA-NN). All other MS files are natively supported, saving computing time.

Spectra are no longer automatically exported to pdf – to save computing time and space. We suggest using pdvviewer to inspect spectra, or load fragpipe results in the fragpipe GUI to inspect and export spectra of interest.

Bug Fixes:

• Fixed a bug preventing the ML algorithm from running properly (version 1.7.1)

• Fixed a bug in the annotation of some MS-identified neoantigens in the list of predictions

• Fixed a bug in the annotation of mutation expression in certain high mutational-load samples

Version 1.7.1

Updates:

• Integration of NeoDiscMS workflow as described in:

Sensitive neoantigen discovery by real-time mutanome-guided immunopeptidomics
Shapiro E. I, Huber F, Michaux J, Bassani-Sternberg M, Nature Communications, 2025, 0.1038/s41467-025-62647-4

• See the description of the workflow and the new configuration file variables in the manual for more information.

• Updated Comet to version: 2024.02_0

• Updated Fragpipe to version: 22.0

• DDA samples are analyzed in DDA+ mode in fragpipe

• Possibility to select which variable (MS_VARIABLE_MODIFICATIONS) and fixed (NEODISCMS_VARIABLE_MODIFICATIONS) modifications to include in the MS analysis. See the description of the configuration file in the manual.

• Sequenza: Updated copy-number estimation (ratio.priority=True) for better performance on WES data

• Various bug fixes

Version 1.7.0 – bugfix 2

Bug Fixes:

• Improvement in the -cleandnafq and -cleanrnafq outputs: support for a wider range of FASTQ sequence identifier formats.

• Addition of light and full modes to -cleandnafq and -cleanrnafq:

light mode reformats FASTQ read identifiers into a format compatible with GATK and Picard tools.

full mode performs the same reformatting and also deduplicates reads.

• Fixed a bug affecting the combination of MS-identified peptides when only HLA-I or HLA-II injections were measured, but predicted binders existed for both HLA-I and HLA-II.

Version 1.7.0 – bugfix 1

To enhance the download experience, the resources have been separated from the container. As a result, the installation process has changed slightly, as reflected in the updated Manual. Additionally, a few bugs have been fixed in the Software and Resources.

Bug Fixes:

• Fixed issue with running MS analysis using DIA only.

• Resolved problem when running MS analysis with only HLA-I or HLA-II alleles.

• Corrected underestimation of mutational load when using gencode_v43 as the capture kit.

• Added –no-home and –cleanenv options to the Singularity command to prevent loading environment variables in the container.

• Various minor bug fixes.

Version 1.7.0

First release of NeoDisc, as published in:

A comprehensive proteogenomic pipeline for neoantigen discovery to advance personalized cancer immunotherapy
Huber F, et al. Nature Biotechnology, 2024, 10.1038/s41587-024-02420-y